Partyline: Can I interface a Telecast Copperhead 3200 or Pro Camera transceiver to a Clear-Com 2-wire or 4-wire system?

Partyline: Can I interface a Telecast Copperhead 3200 or Pro Camera transceiver to a Clear-Com 2-wire or 4-wire system?

Answer:  Yes, the Copperhead 3200 interface can be fitted with either a Clear-Com 2-wire PL module, a 4-wire module or an RTS 2-wire PL module.  The module is installed on the base station rear panel, the base station feeds the fiber signals (video, audio and IC) out to the camera transceiver module that is fitted to the camera. 
4-wire module connections & 2-wire Clear-Com configured module connections:











Custom CAT-5 cable wiring for 4-wire connection from Eclipse Matrix frame to Copperhead 3200 camera transceiver:







































Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.