Partyline: Can I interface a Telecast Copperhead 3200 or Pro Camera transceiver to a Clear-Com 2-wire or 4-wire system?
Answer: Yes, the Copperhead 3200 interface can be fitted with either a Clear-Com 2-wire PL module, a 4-wire module or an RTS 2-wire PL module. The module is installed on the base station rear panel, the base station feeds the fiber signals (video, audio and IC) out to the camera transceiver module that is fitted to the camera.
4-wire module connections & 2-wire Clear-Com configured module connections:
Custom CAT-5 cable wiring for 4-wire connection from Eclipse Matrix frame to Copperhead 3200 camera transceiver: