  1. LQ SIP  (Optional Licensed)

...

V4.1.35.0:

Enhancements:
➢ GPI Control of MIC ON for HelixNet HMS and HRM
➢ HMS restore functionality allowing configuration of cold standby units
➢ Front panel Role selection list sorted alphabetically
➢ Reset functions terminology clarification
➢ HRM - Resource load on HMS can be manually allocated
➢ CCM - System resource counter
➢ USB Logging - Non-volatile support information
➢ Time synchronization for support information
➢ SSH access disabled
➢ Contour filter default changed to OFF
➢ Datasheets/Documentation: Network Specifications added

Bug fixes:
➢ BUG: HMS power-up issue resulting in one-way audio on HLI modules
➢ BUG: HRM Expansion slave power-up connection
➢ BUG: HLI-2W2 – Null parameters are not always recalled
➢BUG: Roles do not update from the endpoint menu
➢ BUG: GPO assignment limits outside of module and channel hosts
➢ BUG: CCM edited endpoint names are not stored
➢ BUG: Missing hostname when not in DHCP
➢ BUG: CCM Display Corruption
➢ BUG: HXII-BP Talk key stays lit when set to Disabled
➢ BUG: CCM Add Role dialog sticks to the Default role
➢ BUG: Jitter buffers do not fully expand on highly loaded Powerlines


IMPORTANT CHANGE– PLEASE NOTE! CCM New Default Password