I have some ICS-1008 panels working on my ECS frame and I’m upgrading to EHX. Will these panels work after the upgrade?

Yes. They will.

If going from Matrix+3 to ECS or EHX, the panels will need to be upgraded. The main board EEPROM will need to be reprogrammed.

Board Location: Main Board - IC11

Clear-Com Part Number: 710481Z REV E

Description: IC FLASH 1M PARALLEL 32pin EE-PROM

EEPROM (Recommended) Part Number: SST - 29EE010 - 70-4C-PHE - 0835231-WB

Data Sheet: https://www.dataman.com/media/datasheet/SST/SST29EE010_SST29LE010_SST29VE010.pdf

Reprogramming steps = Work In Progress (will be posted once complete and verified)