We have upgraded a matrix from ECS 524 to EHX V7.0
Theupgrade The upgrade to EHX gives the customer a higher maximum number of ports compared toECS to ECS ...
Can you check why I have this result without adding new card
and get an error message when adding new card and why i can't add morethan more than 16 ports to St-1 matrix?
Can youreply, please to the following :In my system
St-0 matrix has:
6 x mvxa16
2 x madi 64
1 x fiber count 192
How much MVXA16 cards can we add in this matrix with ECS 5.2 ?
How much MVXA16 card can we add in this matrix with EHX ?
...
Answer: At ECS 5.2.4 you had the following limits:
240 audio
...
ports
496 time-slots
...
Every audio port used up onetimeone time-slot as well. So a 64 port MADI card would use 64 audio ports and 64time64 time-slots.
An E-FIB set to 192 trunks uses 0 audio ports (as long as there areno are no cards with audio parts in a slot with
a higher numberafter it ) and 192 time-slots.
At 7.0 and later you have theselimitsthese limits:
496 time-slots No more audio port limit.
You canhover can hover the mouse cursor over one of the bars (in the EHX resource chart) to see the
current count as well asthe as the limit. St
St-0 matrix has :
6 x mvxa16
2 x madi 64
1 x fiber count 192
How much MVXA16 cards can we add in this matrix with ECS 5.2 ?
96 MVX + 128 MADI = 224 audio ports (to 240 limit you have 16 left)
96 MVX + 128 MADI + 192 FIBRE = 416 time-slots (80 time-slots left)
You can add 1 MVX card (independent of fibre count because you are closer to
...
the audio ports limit)
How much MVXA16card MVXA16 card can we add in this matrix with EHX ?
96 MVX + 128 MADI + 192 FIBRE = 416 (80 time-slots left)
You can add 5 MVX card
St-1 matrix has :
6 x mvxa16
1 x madi 64
2 x E-Que SPLITTER
26 x BELTPACKS (Hardware units)
32 x BELTPACKS (roles)
1 x fiber count 192
How much MVXA16 cards can we add in this matrix with ECS 5.2 ?
96 MVX + 64 MADI + 32 BP roles = 192 audio ports (48 left)
96 MVX + 64 MADI + 120 E-QUE splitter + 192 FIBRE = 472 time-slots (24 left)
you can add 1 MVX card
How much MVXA16 card can we add in this matrix with EHX ?
96 MVX + 64 MADI + 120 E-QUE splitter + 192 FIBRE = 472 time-slots (24 left)
you can add 1 MVX card (can be increased by
...
reducing fibre count)